Customer: framas

Industry: Footwear / Sporting goods

Location: Pirmasens, Germany

Company Description: framas develops and manufactures plastic components and molds for performance sports footwear, including football boot outsoles.

Application: Injection molding, conformal cooling.

Summary

Seventy seconds. That’s how long it took to cool this football boot outsole mold with conventional drilled channels.

framas’ engineers had already done the hard part: their conformal cooling design brought it down to a solid 44 seconds. A strong result, but we thought we could push further.

Instead of starting from scratch, we used ToffeeX’s Seed Design feature. We gave ToffeeX framas’ existing channels and a simple brief: stay close to this, but find something better. In simulation, the result cools the mold 49% faster than drilled channels and 18% faster than framas’ conformal design.

ToffeeX-optimised conformal cooling channels built from framas' seed design around a football boot outsole cavity in an injection mould insert
Mold cooling channel network design in ToffeeX. The shoe outsole is visible in red, the seed design in green, and the optimized channels in blue.

Why cooling time matters in footwear molding

Performance outsoles are injection molded: TPU or similar polymers are injected into a steel mold, packed under pressure, cooled until the part is stable, then ejected. An outsole cavity is anything but simple, with stud housings, ejector-pin bosses and thin-to-thick wall transitions packed across a large, curved surface.

Diagram of an injection moulding cycle showing fill, pack, cooling and ejection, with cooling as the largest phase
Cooling is usually the longest phase of the injection moulding cycle.

Cooling is usually the largest share of the cycle, often more than half. For a manufacturer running high-volume production, even a modest cut in cooling time compounds into a large amount of reclaimed machine capacity.

From drilled channels to physics-driven conformal cooling

Conventional mold cooling relies on straight, drilled channels, because a drill can only cut in a straight line. That’s a hard geometric constraint that has nothing to do with where the part actually needs cooling; channels end up wherever a drill can reach, not necessarily near the thick sections, the stud bosses, or the areas farthest from the parting line.

The result is uneven cooling: some regions of the part cool (and shrink) faster than others, driving warpage, sink marks, and inconsistent dimensions, and the whole shot has to wait for the slowest-cooling region before the part can be safely ejected.

Conformal cooling channels solve the geometric problem by following the contour of the part surface at a roughly constant offset distance, rather than running in straight lines. Because they hug the cavity shape, they cool more evenly and generally faster than drilled channels, but a conventionally designed conformal channel is still a reasonable guess at the right channel shape, not the mathematically optimal one.

Schematic comparing drilled cooling channels, conventional conformal cooling and ToffeeX physics-driven cooling channels around a shoe outsole
From drilled lines to physics-driven networks: three ways to cool the same outsole cavity (schematic).

This is where metal additive manufacturing changes what’s possible. Because an LPBF metal printer builds up material layer by layer rather than removing it with a drill, channels are no longer limited to straight lines, or even to a single offset surface.

They can branch, merge, vary in cross-section, and route through the tool exactly where the thermal load demands it. That opens the door to designing the channel network with physics rather than intuition: using topology optimization to let the true objective determine the shape, subject only to what LPBF can actually print.

The benchmark designs

framas supplied two reference designs for the same outsole mold: the original drilled channels (70 s cooling time) and their own hand-designed conformal layout (44 s). Comparing against both shows how much comes from conformal geometry alone, and how much from optimization on top of it.

Designing the cooling channels with ToffeeX

Setup. The design domain was the volume around the outsole cavity, with the mold’s structural features fixed as non-design regions. Four independent water circuits, each with its own inlet and outlet, distribute coolant across different zones of the sole for a more uniform temperature. Each circuit runs at framas’ operating point of 10 L/min with 30 °C inlet water. The material was set to an LPBF-printable, corrosion-resistant martensitic tool steel, Printdur HCT, so conductivity and manufacturing limits matched what can actually be printed.

ToffeeX platform setup for the framas outsole mould: the shoe outsole, framas’ reference cooling channels used as the seed design, and the design domain
The setup in ToffeeX: outsole cavity (orange), framas’ reference cooling channels used as the seed (blue) and the design domain (wireframe).

Seeding. Rather than an unconstrained optimization, we used framas’ conformal channels as the starting point and set how far the design may move away from them. That changes the question from “what is the theoretical optimum?” to “what is the best design framas can still manufacture, qualify and fit into the existing mold?” We ran two levels, 10% and 25% seed, giving a family of related designs and a clear view of which changes drive the improvement.

Selection and validation. Designs were checked for thermal performance (cooling time, temperature uniformity) and for printability: minimum feature size, self-supporting angles, and powder removal through the ports. The selected design was then validated with a full thermal-fluid simulation against both benchmarks under identical conditions (10 L/min, 30 °C inlet).

Side-by-side simulated temperature maps of the football boot outsole mould with ToffeeX cooling channels at 10% seed (38 s) and 25% seed (36 s)
ToffeeX Seed Design at two levels: the 25% seed reshapes the channels further from framas’ reference and cools 2 s faster.

Results

Bar chart of simulated outsole mold cooling times: drilled channels 70 s, framas conformal 44 s, ToffeeX 10% seed 38 s, ToffeeX 25% seed 36 s
Simulated cooling time for each design under identical conditions (10 L/min, 30 °C inlet).

Why it matters

  • Shorter cycles, more parts. Cooling drives cycle time. Seconds saved on every shot add up to more outsoles per mold, per shift, on the same machine.
  • Lower cost per part. Less machine time and energy per part, without adding tooling or presses.
  • More uniform cooling. Channels placed where the heat is help reduce uneven shrinkage behind warpage and sink marks.
  • Expertise you keep. Seed Design builds on your engineers’ work instead of replacing it, so proven design intent carries through to the optimized result.
  • Gains where intuition stops. When a design is already good, the next improvement is hard to find by hand. ToffeeX explores the design space and finds it.

Tailored for you.