Topology-Optimized Cold Plates Cut CPU and GPU Temperatures by up to 35 °C

EOS logo

Customer: EOS

Industry: Additive Manufacturing

Location: Krailling, Germany

Company Description: EOS is a leading technology provider for industrial 3D printing of metals and polymers. Founded in 1989 and family-owned, the company supplies additive manufacturing systems, materials, software and services to manufacturers worldwide.

Application: Liquid cold plates for an Intel Xeon E5‑1620 CPU and an NVIDIA Quadro M4000 GPU.

Manufacturing System: EOS M 290.

Materials: EOS Aluminium AlSi10Mg, APWorks Scalmalloy, EOS Aluminium Constellium CP1.

Summary

On a conventional cooler with copper heat pipes, an Intel Xeon E5‑1620 settled at 80 °C; the NVIDIA Quadro M4000 GPU beside it, on a heat-pipe cooler of its own, ran at 70 °C.

Both chips can run at those temperatures, but every degree is margin that could otherwise go to higher clock speeds, quieter pumps, warmer coolant or a longer service life.

With EOS, we set out to see how much of that margin a better cold plate could win back. We designed one liquid cold plate for each chip in ToffeeX, using thermo-fluid topology optimization to shape the inside of the plate. On the test bench, the ToffeeX CPU plate ran 30 °C cooler than the heat-pipe baseline, and the GPU plate ran 35 °C cooler.

Cut-away 3D renders of the topology-optimized CPU and GPU liquid cold plates, each with inlet and outlet pipes on top and an internal cooling structure in the base
The two ToffeeX cold plates, cut open to show the internal flow paths: the CPU design (left) and the GPU design (right).

Why chip temperature matters

When a processor gets too hot, it lowers its clock speed to protect itself, so performance drops just as the workload is heaviest. Heat wears the hardware well before that point, too, because the mechanisms that age electronics all speed up as the chip gets warmer.

The cold plate is the first link in the cooling chain and has the least room to work in. It has to move the chip’s entire heat load through a contact patch a few centimetres across and into the coolant. How well it does that depends on the geometry inside: where the coolant goes, how fast it moves and how much metal surface it touches on the way.

From heat pipes to physics-driven flow paths

Most cold plates are built from shapes a machine can cut, such as straight channels, parallel fins and rows of pins. The layout follows what the tool can reach, and the coolant goes wherever that layout sends it, whether or not the heat is there.

The baseline in this study is a conventional cooler with copper heat pipes. Heat pipes are a proven, widely used solution, but they only move the heat: it still has to leave through a separate fin stack. A liquid cold plate takes the heat straight into the coolant at the chip, and how well it does that depends on the geometry inside.

Metal 3D printing removes the tooling limit. A printed channel can curve, split, rejoin, and change width wherever it needs to, which leaves the harder question of which shape to build. Topology optimization answers it. ToffeeX simulates the coolant flow and the heat transfer together, then adds metal where it helps pull heat into the coolant and keeps channels open where the coolant needs to flow. The engineer sets the objective and the limits, and the software finds a shape that meets them.

The project also demonstrates the versatility of metal additive manufacturing, enabling the use of different aluminium alloys, complex geometries and integrated designs. The PC cooling assembly showcases how these capabilities can be combined to create application-specific solutions that would be impossible to achieve through conventional manufacturing.

Designing topology-optimized cold plates with ToffeeX

Each cold plate started as an empty design envelope with three fixed features: an inlet port, an outlet port, and the face that sits on the chip. ToffeeX was free to fill everything in between with aluminium or coolant. The two chips needed separate designs because they are packaged so differently. The Xeon E5‑1620 is a 130 W quad-core CPU that spreads its heat through an integrated heat spreader, while the Quadro M4000 is a 120 W workstation card whose GM204 GPU is a bare 398 mm² die.

Both plates had the same objective: carry as much heat as possible from the chip face into the coolant for as little pressure loss as possible. That one objective produced two very different plates.

  • The CPU plate sweeps the coolant down a curved channel onto the centre of the base. From there it fans out through a branching, almost coral-like fin structure before collecting at the outlet.
  • The GPU plate drops the coolant straight down a riser into a shallow, finned chamber over the chip. The flow crosses the full width of the base and leaves through a second riser in the opposite corner.
3D renders of the CPU and GPU cold plates cut horizontally just above the chip face, showing the branching, coral-like fin network of the CPU plate and the curved fins of the GPU plate
Inside the plates, cut horizontally just above the chip contact face: the CPU plate (left) has a branching, coral-like fin network; the GPU plate (right) has curved fins that spread the flow across the chamber.
Cut-away CPU and GPU cold plates side by side with coolant flow streamlines coloured by velocity: in the CPU plate the coolant hits the centre of the base and fans out, in the GPU plate it drops down a riser and crosses a finned chamber
Simulated coolant flow, coloured by velocity from blue (slow) to red (fast) on the same 0–1 m/s scale. The CPU plate (left) drives coolant onto the centre of the base and fans it outward. The GPU plate (right) sends it down a riser and across a finned chamber over the chip.
Front and angled 3D views of a topology-optimized CPU cold plate with flow lines: fast flow in the two vertical ports, slow looping flow spread through the fin structure in the base
The full coolant path through the ToffeeX CPU cold plate in 3D, on the same 0–1 m/s velocity scale. Coolant runs fast through the ports, then slows and spreads out as it passes through the fin structure in the base.
The ToffeeX web app showing a simulation run of the topology-optimized CPU cold plate, with coolant streamlines coloured by velocity, the run and geometry panels on the left and viewer controls on the right
The CPU cold plate in ToffeeX. The same web app that generated the design also simulates it, here showing the coolant streamlines coloured by velocity.

Before testing, each design went through a full conjugate heat transfer simulation in ToffeeX, which solves the coolant flow and the heat conduction in the metal together.

Results

The ToffeeX cold plates were then printed by EOS using an EOS M 290 metal additive manufacturing system and tested against the copper heat-pipe coolers used as the baseline on the Xeon E5-1620 and the Quadro M4000.

Photos of the liquid-cooled test PC with the 3D-printed ToffeeX cold plates installed on the CPU and GPU, and two printed metal cold plates cut open to show their internal fins
The 3D-printed ToffeeX cold plates in the test build: the full assembly, the CPU and GPU plates in the cooling loop, and two printed plates cut open to show the internal structure.

The CPU’s maximum temperature fell from 80 °C to 50 °C, and the GPU’s from 70 °C to 35 °C.

Bar chart of measured maximum temperature. Intel Xeon E5-1620 CPU: heat-pipe baseline 80 °C, ToffeeX 50 °C. NVIDIA Quadro M4000 GPU: heat-pipe baseline 70 °C, ToffeeX 35 °C
Measured maximum temperature with the heat-pipe baseline and ToffeeX cold plates. The ToffeeX designs ran 30 °C cooler on the CPU and 35 °C cooler on the GPU.
Measured maximum temperatureHeat-pipe baselineToffeeXReduction
CPU (Intel Xeon E5‑1620)80 °C50 °C−30 °C
GPU (NVIDIA Quadro M4000)70 °C35 °C−35 °C

Why it matters

A chip running 30 °C cooler sits far from its throttling limit, so it holds full speed under sustained load, and the lower temperature slows the wear mechanisms that age electronics. The same margin can instead go to a more powerful chip, a higher clock speed, or warmer coolant, which is cheaper to supply.

See the cold plates at Formnext 2026

The CPU and GPU cold plates will be on show, running, at the EOS booth at Formnext 2026 in Frankfurt, 17–20 November: Hall 12.0, Booth D71. Stop by to see them in operation, then visit the ToffeeX team at Hall 12.0, Booth A129.